PROJECTS

9/2/21 700 TON MT MILACRON

P-108 BLOWS OFF MOUNT

ORIFACE PLUGED WITH BRASS ON PRESSURE CONTROL CLEAN

8/22/21 GOLD STAR

OIL TEMP OVER SET POINT WHEN PUMP RUNS BUT MACHINE IS OUT OF CYCLE

HAET EXCHANGE IS CLEAN OIL SIDE OF EXCHANGER IS COATED WITH FILM pump runs at 160 deg needs replaced

8/31/2021 MILACRON 700-70 IMM

NO INJECTION FORWARD

INJECTION VALVE IS GOOD PUMPS STOPPED WORKING REPLACED PUMPS

8/15/2021 AP INJECTION SPEED ISSUE SM90 TSV

LOOSE WIRES ON CONTROL

8/15/21 BOY 80M

NO PUMP OR HEATS

LOOSE INJECTION UNIT PLUG LOOSE WIRE ROBOT PLUG REPLACE RELAY AIM CARD

8/7/21 VAN DORN 1100CC165-0104

WILL NOT CYCLE

LS5 LOOSE DOOR BENT LS106 LOOSE

8/5/21 KRAUSS 1300-8100MX

MEMORY ISSUES

RELOADED SOFTWARE

7/23/21 MILACRON VH1000-179

NO HIGH PRESSURE ALL FUNCTION MOVING SLOW

ALL PUMPS ON MACHINE ARE BAD AND NEED REPLACED

7/22/21 MILACRON MM550-105

CUSTOMER INSTALLED REBUILT CLAMP END

LEVELED MACHINE AND TESTED MACHINE

7/20/21 ENGEL TL80/40VS

no control of machine

calibrated machine and tested

Toshiba ec45v10 fc40-1

calibrate machine and test

Milacron vl1650-232

leaking oil on clamp piston

replaced clamp piston seal and test machine

Milacron VL 1650-232

pump not working

installed a new pump coupler

Milacron MM725-116

oil leak on clamp

replaced clamp seals and test machine

Milacron MH725-140

FHDs alarm current channel 1

A188 drawing too much current. lowered max in program and told customer to order a new A188

Milacron MM880-14

injection chatter and the end of injection

calibrated injection valve output

Van Dorn 1100-

not reading ejector position

transducer is bad and needs replaced

Van Dorn 120HT500

calibrate Machine and preform a PM on machine

Van Dorn 120HT6F

calibrate machine and preform a PM on machine

Level machine

Mitsubishi 1600MM III W340

machine not running well parts are no longer available

installed new controls with upgraded touch screen CPU

Van Dorn 230RS14F

calibrate machine and PM machine

Level machine

Milacron MH600-76

Will not boot error 00047

Main CPU is bad and needs replaced part is $5600 this would be a good machine to upgrade

Toshiba ISE610

clamp binds during open and close operation

replaced ware strips on clamp and level machine test for operation

Milacron MM 550-70

Control had 480 volt sent into it.

removed all controls and replace with a new touch screen control system and test machine

HPM 230 Maco 4000

ejectors not working found a bad output card

Milacron 850

screw not going back, worn check ring