PROJECTS
9/2/21 700 TON MT MILACRON
P-108 BLOWS OFF MOUNT
ORIFACE PLUGED WITH BRASS ON PRESSURE CONTROL CLEAN
8/22/21 GOLD STAR
OIL TEMP OVER SET POINT WHEN PUMP RUNS BUT MACHINE IS OUT OF CYCLE
HAET EXCHANGE IS CLEAN OIL SIDE OF EXCHANGER IS COATED WITH FILM pump runs at 160 deg needs replaced
8/31/2021 MILACRON 700-70 IMM
NO INJECTION FORWARD
INJECTION VALVE IS GOOD PUMPS STOPPED WORKING REPLACED PUMPS
8/15/2021 AP INJECTION SPEED ISSUE SM90 TSV
LOOSE WIRES ON CONTROL
8/15/21 BOY 80M
NO PUMP OR HEATS
LOOSE INJECTION UNIT PLUG LOOSE WIRE ROBOT PLUG REPLACE RELAY AIM CARD
8/7/21 VAN DORN 1100CC165-0104
WILL NOT CYCLE
LS5 LOOSE DOOR BENT LS106 LOOSE
8/5/21 KRAUSS 1300-8100MX
MEMORY ISSUES
RELOADED SOFTWARE
7/23/21 MILACRON VH1000-179
NO HIGH PRESSURE ALL FUNCTION MOVING SLOW
ALL PUMPS ON MACHINE ARE BAD AND NEED REPLACED
7/22/21 MILACRON MM550-105
CUSTOMER INSTALLED REBUILT CLAMP END
LEVELED MACHINE AND TESTED MACHINE
7/20/21 ENGEL TL80/40VS
no control of machine
calibrated machine and tested
Toshiba ec45v10 fc40-1
calibrate machine and test
Milacron vl1650-232
leaking oil on clamp piston
replaced clamp piston seal and test machine
Milacron VL 1650-232
pump not working
installed a new pump coupler
Milacron MM725-116
oil leak on clamp
replaced clamp seals and test machine
Milacron MH725-140
FHDs alarm current channel 1
A188 drawing too much current. lowered max in program and told customer to order a new A188
Milacron MM880-14
injection chatter and the end of injection
calibrated injection valve output
Van Dorn 1100-
not reading ejector position
transducer is bad and needs replaced
Van Dorn 120HT500
calibrate Machine and preform a PM on machine
Van Dorn 120HT6F
calibrate machine and preform a PM on machine
Level machine
Mitsubishi 1600MM III W340
machine not running well parts are no longer available
installed new controls with upgraded touch screen CPU
Van Dorn 230RS14F
calibrate machine and PM machine
Level machine
Milacron MH600-76
Will not boot error 00047
Main CPU is bad and needs replaced part is $5600 this would be a good machine to upgrade
Toshiba ISE610
clamp binds during open and close operation
replaced ware strips on clamp and level machine test for operation
Milacron MM 550-70
Control had 480 volt sent into it.
removed all controls and replace with a new touch screen control system and test machine
HPM 230 Maco 4000
ejectors not working found a bad output card
Milacron 850
screw not going back, worn check ring